Product DescriptionInstall DetectorThe detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat s

  • Model: TLD-110P
Product Description
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Install Detector
The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around
other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as “Loop installation guide”).
Wire Diagram
Chisung Intelligence Technology (Shenzhen) Co., Limited | China Guangdong
Operation and Indication
After power on, the detector will calibrate
automatically, and the calibration process
is about 3 seconds. During calibration, there should be no parking on the coil. When the calibration is successful, when there is
a car passing on the coil, the "status" indicator on the panel lights up, and the output relay is switched on; if the coil is not detected in the calibration process or the coil inductance is not within the allowable range, the green LED indicator will keep flashing

Sensitivity

The sliding switch on the panel is used for sensitivity adjustment. There are three gears: H is high sensitivity, M is medium sensitivity and l is low sensitivity. During the trial operation, the sensitivity should be set at a lower gear. After the actual test, if there is no response to the vehicle detection, the sensitivity should be adjusted to a higher gear. This is repeated until the vehicle detector works stably and normally.
【Attention】If the detector does not work normally, you must check the loop and wiring at first
whether the feeder is twisted or damaged. Then adjust the frequency or the sensitivity

Output Relay

The output mode of the relay is the presence output, that is, when the vehicle enters the coil, it will be
switched on until the vehicle leaves the coil; the relay will be disconnected.


Model Number
TLD-110P
Product name
single channel loop detector TLD-110P
Supply voltage
AC 100-260 V
Voltage tolerance
AC +10% / -15%
Output relays
240V/5 A AC
Operating temperature
-25℃-+65℃;
Storage temperature
-40℃-+80℃
Reaction time
100ms
Signal holding time
Unlimited
Sensitivity
Adjustable in 3 increments
Loop inductance
50uH to 1000uH(the best is from 100uHto 300uH)
Loop inductance
50uH to 1000uH(the best is from 100uHto 300uH)
Loop connection wiring
Max length 20 meters, twisted at least 20 times per meter
Size 
100×40×30mm (L×W×H)
Weight
70G