Expressway Barrier Gate CSEDZ011
Expressway Barrier Gate CSEDZ011: Max boom size:2500mm in length, 75mm in diameter. Opening time: 0.6seconds
- Model:
Expressway Barrier Gate CSEDZ011: Max boom size:2500mm in length, 75mm in diameter. Opening time: 0.6seconds
Specification of the mechanism and motor controller
Item /model | CSEDZ011 | CSEDZ012 |
Max boom size | 2500mm in length, 75mm in diameter | 3000mm in length, 75mm in diameter |
Opening time |
0.6seconds |
0.9 seconds |
Energy Consumption |
Max 150w |
Max 100w
|
Housing Material | Powder-coated Aluminum | Powder-coated Aluminum
|
Machine weight(no boom) | 43kg | 43kg |
Working Temp |
-40 to +50℃ |
-40 to +50℃
|
MTBF | 10 million times | 10 million times |
Driving unit | Servo Motor
| Servo motor |
IP rating | IP55 | IP55 |
Motor Controller Specification | ||
Board Voltage | 24V DC | 24V DC |
power consumption | 10W | 10W |
Fuse | 5AH | 5AH |
Input qty | 8 | 8 |
Working Temp |
-40 to +50℃ |
-40 to +50℃
|
IP rating | IP20 | IP20 |
Weight | 330g | 330g |
Dimension | L-W-H(mm) | 155-110-60 |
Motor controller diagram and functions
Important notes:
All the interfaces on this controller are only for non-electricity connection.
There are NC and NO inputs available for this machine. NC is recommended. To make it, just put the dip switch 1 to ON position. OFF position is for NO status.
1. NO/NC status adjustable, in dip switch 1, ON for NC, OFF for NO.
2. When power off, the boom will open automatically or stay closed; this is adjustable. In dip switch 2, ON is for automatic open when power off;
3. Automatic stop or automatic reverse when the machine meets external obstruction. In dip switch 3, ON is for automatic stop and off is for automatic reversing;
4. Auto closing function and the closing time is adjustable. Dip switch5,6,7,8 are for it and the delaying time is 1s,2s,3s,4s,5s,8s,10s,15s,20s,25s,30s,35s,40s,50s,60s.
5. The boom angle in up position adjustable, like 60degree, 70degree, 80degree and 90degree. And the dip switch is another independent one(1 2 switch).
6. Maintenance mode available, convenient for possible repairing and adjusting.
7. RS485 serial communication available for computer control.
8. Push button interface and remote control interface are available and separate.
9. Emergent stop input interface available.
10. Traffic light/alarm light interface